BIMgravity — Revit IFC export kit For the two US rule packs: "US Owner Requirements — Model Data" (the data check) and "US Handover — COBie Asset Data" (the handover check). Version 1.1.0, 2026-11-12. HOW TO READ THIS [checked] seen in a real Revit IFC export used to test the packs. [unchecked] the setting or behavior as we understand it, NOT yet confirmed on a test export. Setting names can differ between versions of the Revit IFC exporter. Do one test export and run it through BIMgravity before relying on it. ------------------------------------------------------------------------------ 1. EXPORT SETUP (File > Export > IFC > Modify setup) ------------------------------------------------------------------------------ IFC version ........ IFC4 Reference View, or IFC 2x3 Coordination View 2.0. Both are checked by the packs. [checked] Property sets ...... turn ON "Export IFC common property sets" (Pset_WallCommon, Pset_DoorCommon ...). [checked] turn ON "Export user defined property sets" and point it to the mapping file in section 3. [unchecked] Rooms / spaces ..... export rooms (IfcSpace). The data check asks every space for a number, a name and a level. [checked] Classification ..... the exporter can write classification references (Uniformat from Assembly Code, OmniClass). Confirm in the result that IfcClassificationReference exists: one Revit IFC4 test export had it, one IFC2x3 export had none. [unchecked: which setting drives it] ------------------------------------------------------------------------------ 2. WHAT EACH RULE READS, AND WHERE REVIT USUALLY PUTS IT ------------------------------------------------------------------------------ Data check · US Owner Requirements (rule ids US-OWN-*) Type name (walls, doors, MEP) .... IfcObject.ObjectType — Revit writes the family and type name. [checked] Level (walls, spaces) ............ contained in / part of an IfcBuildingStorey. [checked] Level (MEP equipment) ............ story OR an IfcSpace; Revit places equipment in the room's space. [checked] Interior / exterior .............. Pset_WallCommon.IsExternal, Pset_DoorCommon.IsExternal. [checked] Load-bearing ..................... Pset_WallCommon.LoadBearing. [checked] Door type mark ................... Pset_DoorCommon.Reference (must not be empty). [checked] Room number / room name ......... IfcSpace.Name / IfcSpace.LongName. [checked] Classification ................... any IfcClassificationReference on the element (any system). [checked] Handover check · US Handover, COBie (rule ids US-HO-*) Asset tag ........................ IfcElement.Tag. Revit fills it with the element id by default, so this is met on most exports; map your own tag if your owner asks for one. [checked: id; unchecked: how to override] Manufacturer ..................... Pset_ManufacturerTypeInformation.Manufacturer. A Revit IFC4 test export filled it on light fixtures and terminals, not on doors. [checked] Which Revit parameter feeds it (probably the type "Manufacturer"). [unchecked] Model number ..................... Pset_ManufacturerTypeInformation.ModelLabel. Not found in any test export: map it (section 3). [checked: absent] Warranty ......................... Pset_Warranty.WarrantyPeriod. Not found in any test export: map it (section 3). Classification ................... as in the data check. Equipment in a space ............. MEP equipment contained in an IfcSpace. [checked] Space in a zone .................. IfcSpace assigned to an IfcZone. A Revit IFC4 MEP test export had 51 IfcZone and 87 of 163 spaces in one. [checked] Which Revit feature produced them (HVAC zones, or a room parameter "ZoneName"). [unchecked] ------------------------------------------------------------------------------ 3. USER-DEFINED PROPERTY SET MAPPING (save as a .txt file) [unchecked] ------------------------------------------------------------------------------ Format as we understand it: a "PropertySet:" line (name, I = instance or T = type, IFC entity), then one TAB-separated line per property: IFC property name, IFC data type, Revit parameter name. Replace the Revit parameter names with the ones your template uses. PropertySet: Pset_ManufacturerTypeInformation T IfcElement Manufacturer Label Manufacturer ModelLabel Label Model PropertySet: Pset_Warranty T IfcElement WarrantyPeriod Text Warranty Duration ------------------------------------------------------------------------------ 4. NOT CHECKED BY THESE PACKS ------------------------------------------------------------------------------ Fire ratings, occupancy, exit doors, door clear width and sprinklers belong to the code data check. A check of model data, not a code approval. Your model file never leaves your computer. The file name, its size and the property values the rules need are sent to check them. The AI receives the results of the check, never your model or its elements.